Ice Buildup
Oct 27, 2017

Under certain conditions of temperature and humidity, ice can form on a refrigeration dehumidifier's evaporator coils. The ice buildup can impede airflow and eventually form a solid block encasing the coils. This buildup prevents the dehumidifier from operating effectively, and can cause water damage if condensed water drips off the accumulated ice and not into the collection tray. In extreme cases, the ice can deform or distort mechanical elements, causing permanent damage.

Better-quality dehumidifiers may have a frost or ice sensor. These will turn off the machine and allow the ice-covered coils to warm and defrost. Once defrosted, the machine will automatically restart. Most ice sensors are simple thermal switches and do not directly sense the presence or absence of ice buildup. An alternative design senses the impeded airflow and shuts off the cooling coils in a similar manner.